Molecular imprinting coupled with electrochemical analysis for plasma samples classification in acute myocardial infarction diagnosticстатья
Статья опубликована в высокорейтинговом журнале
Информация о цитировании статьи получена из
Web of Science,
Scopus
Статья опубликована в журнале из списка Web of Science и/или Scopus
Дата последнего поиска статьи во внешних источниках: 23 ноября 2017 г.
Аннотация:Electroanalysis of myoglobin (Mb) in 10 plasma samples of healthy donors (HDs) and 14 plasma samples of patients with acute myocardial infarction (AMI) was carried out with screen-printed electrodes modified first with multi-walled carbon nanotubes (MWCNT) and then with a molecularly imprinted polymer film (MIP), viz., myoglobin-imprinted electropolymerized poly(o-phenylenediamine). The differential pulse voltammetry (DPV) parameters, such as a maximum amplitude of reduction peak current (A, nA), a reduction peak area (S, nA × V), and a peak potential (P, V), were measured for the MWCNT/MIP-sensors after their incubation with non-diluted plasma. The relevance of the multi-parameter electrochemical data for accurate discrimination between HDs and patients with AMI was assessed on the basis of electrochemical threshold values (this requires the reference standard method (RAMP® immunoassay)) or alternatively on the basis of the computational cluster assay (this does not require any reference standard method). The multi-parameter electrochemical analysis of biosamples combined with computational cluster assay was found to provide better accuracy in classification of plasma samples to the groups of HDs or AMI patients.