SOLID-PHASE ENZYME-LINKED IMMUNOASSAY FOR HERBICIDES SIMAZINE AND ATRAZINEстатья
Информация о цитировании статьи получена из
Web of Science
Статья опубликована в журнале из списка Web of Science и/или Scopus
Дата последнего поиска статьи во внешних источниках: 27 мая 2015 г.
Аннотация:Competitive methods of enzyme-linked immunoassay (EIA) for detecting simazine and atrazine were developed, and conditions providing the optimal performance were found. The sensitivity of EIA increased by an order of magnitude if the samples were preincubated with the antibody, chloride ions were omitted from, the medium, and the herbicide-peroxidase conjugate was treated with urea. The sensitivity thresholds of EIA using labelled antibodies toward simazine and atrazine were 0.05 and 0.1 ng/ml, respectively. The total duration of ELA was 1 to 2 h. These methods can be used for water quality tests.